Raytheon Technologies (France)
companyPuteaux, France
Research output, citation impact, and the most-cited recent papers from Raytheon Technologies (France) (France). Aggregated across the NobleBlocks index of 300M+ scholarly works.
Top-cited papers from Raytheon Technologies (France)
The NIF Power Conditioning System provides the pulsed excitation required to drive flashlamps in the laser’s optical amplifiers. Modular in design, each of the 192 Main Energy Storage Modules (MESMs) storage up to 2.2 MJ of electrical energy in its capacitor bank before delivering the energy to 20 pairs of flashlamps in a 400 μs pulse (10% power points). The peak current of each MESM discharge is 0.5 MA. Production, installation, commissioning and operation of the NIF Power Conditioning continue to progress rapidly, with the goals of completing accelerated production in late 2007 and finishing commissioning by early 2008, all the while maintaining an aggressive operations schedule. To date, more than 80% of the required modules have been assembled, shipped and installed in the facility, representing more that 240 MJ of stored energy available for driving NIF flashlamps. The MESMs have displayed outstanding reliability during daily, multiple-shift operations.
The purpose of this study was to compare Electromyographic (EMG) with Mechanomyo- 1 graphic (MMG) recordings during isometric conditions, and during a simulated load-lifting task. 2 Twenty-two males (age: 25.5 ± 5.3 years) first performed maximal voluntary contractions (MVC) and 3 submaximal isometric contractions of upper limb muscles at 25%, 50% and 75% MVC. Participants 4 then executed repetitions of a functional activity simulating a load-lifting task above shoulder level, 5 at 25%, 50% and 75% of their maximum activity (based on MVC). The low frequency part of the 6 accelerometer signal (< 5 Hz) was used to segment the 6 phases of the motion. EMG and MMG were 7 both recorded during the entire experimental procedure. Root mean square (RMS) and mean power 8 frequency (MPF) were selected as signal extraction features. During isometric contractions, EMG 9 and MMG exhibited similar repeatability scores. They also shared similar RMS vs force relationship, 10 with RMS increasing to 75% MVC and plateaued to 100%. MPF decreased with increasing force to 11 75% MVC. In dynamic condition, RMSMMG exhibited higher sensitivity to changes in load than 12 RMSEMG. These results confirm the feasibility of MMG measurements to be used during functional 13 activities outside the laboratory. It opens new perspectives for future applications in sports science, 14 ergonomics and human-machine interfaces conception.