Melting curves of Cu and Ni were measured in the laser-heated diamond cell to 97 GPa (3800 K) and 60 GPa (2970 K), respectively. The temperatures of Cu are in good agreement with recent theoretical calculations. The Cu melting slope (dT/dP) is about 2.5 times steeper than for Ni. The present results...