NobleBlocks

Herzzentrum Dresden Universitätsklinik

Hospital / health systemDresden, Saxony, Germany

Research output, citation impact, and the most-cited recent papers from Herzzentrum Dresden Universitätsklinik (Germany). Aggregated across the NobleBlocks index of 300M+ scholarly works.

Total works
1.8K
Citations
185.2K
h-index
187
i10-index
2.5K
Also known as
Dresden Heart CenterHeart Center DresdenHeart Center Dresden, University HospitalHerzzentrum DresdenHerzzentrum Dresden GmbH UniversitätsklinikHerzzentrum Dresden GmbH Universitätsklinik an der Technischen Universität DresdenHerzzentrum Dresden UniversitaetsklinikHerzzentrum Dresden UniversitätsklinikUniversity Heart Center Dresden

Top-cited papers from Herzzentrum Dresden Universitätsklinik

Nephrotoxic Effects in High-Risk Patients Undergoing Angiography
P. Aspelin, P Aubry, Sven‐Göran Fransson, Ruth H. Strasser +2 more
2003· New England Journal of Medicine1.1Kdoi:10.1056/nejmoa021833

BACKGROUND: The use of iodinated contrast medium can result in nephropathy. Whether iso-osmolar contrast medium is less nephrotoxic than low-osmolar contrast medium in high-risk patients is uncertain. METHODS: We conducted a randomized, double-blind, prospective, multicenter study comparing the nephrotoxic effects of an iso-osmolar, dimeric, nonionic contrast medium, iodixanol, with those of a low-osmolar, nonionic, monomeric contrast medium, iohexol. The study involved 129 patients with diabetes with serum creatinine concentrations of 1.5 to 3.5 mg per deciliter who underwent coronary or aortofemoral angiography. The primary end point was the peak increase from base line in the creatinine concentration during the three days after angiography. Other end points were an increase in the creatinine concentration of 0.5 mg per deciliter or more, an increase of 1.0 mg per deciliter or more, and a change in the creatinine concentration from day 0 to day 7. RESULTS: The creatinine concentration increased significantly less in patients who received iodixanol. From day 0 to day 3, the mean peak increase in creatinine was 0.13 mg per deciliter in the iodixanol group and 0.55 mg per deciliter in the iohexol group (P=0.001; the increase with iodixanol minus the increase with iohexol, -0.42 mg per deciliter [95 percent confidence interval, -0.73 to -0.22]). Two of the 64 patients in the iodixanol group (3 percent) had an increase in the creatinine concentration of 0.5 mg per deciliter or more, as compared with 17 of the 65 patients in the iohexol group (26 percent) (P=0.002; odds ratio for such an increase in the iodixanol group, 0.09 [95 percent confidence interval, 0.02 to 0.41]). No patient receiving iodixanol had an increase of 1.0 mg per deciliter or more, but 10 patients in the iohexol group (15 percent) did. The mean change in the creatinine concentration from day 0 to day 7 was 0.07 mg per deciliter in the iodixanol group and 0.24 mg per deciliter in the iohexol group (P=0.003; value in the iodixanol group minus the value in the iohexol group, -0.17 mg per deciliter [95 percent confidence interval, -0.34 to -0.07]). CONCLUSIONS: Nephropathy induced by contrast medium may be less likely to develop in high-risk patients when iodixanol is used rather than a low-osmolar, nonionic contrast medium.

Transcatheter Aortic Valve Implantation in Failed Bioprosthetic Surgical Valves
Danny Dvir, John G. Webb, Sabine Bleiziffer, Miralem Pašić +4 more
2014· JAMA917doi:10.1001/jama.2014.7246

IMPORTANCE: Owing to a considerable shift toward bioprosthesis implantation rather than mechanical valves, it is expected that patients will increasingly present with degenerated bioprostheses in the next few years. Transcatheter aortic valve-in-valve implantation is a less invasive approach for patients with structural valve deterioration; however, a comprehensive evaluation of survival after the procedure has not yet been performed. OBJECTIVE: To determine the survival of patients after transcatheter valve-in-valve implantation inside failed surgical bioprosthetic valves. DESIGN, SETTING, AND PARTICIPANTS: Correlates for survival were evaluated using a multinational valve-in-valve registry that included 459 patients with degenerated bioprosthetic valves undergoing valve-in-valve implantation between 2007 and May 2013 in 55 centers (mean age, 77.6 [SD, 9.8] years; 56% men; median Society of Thoracic Surgeons mortality prediction score, 9.8% [interquartile range, 7.7%-16%]). Surgical valves were classified as small (≤21 mm; 29.7%), intermediate (>21 and <25 mm; 39.3%), and large (≥25 mm; 31%). Implanted devices included both balloon- and self-expandable valves. MAIN OUTCOMES AND MEASURES: Survival, stroke, and New York Heart Association functional class. RESULTS: Modes of bioprosthesis failure were stenosis (n = 181 [39.4%]), regurgitation (n = 139 [30.3%]), and combined (n = 139 [30.3%]). The stenosis group had a higher percentage of small valves (37% vs 20.9% and 26.6% in the regurgitation and combined groups, respectively; P = .005). Within 1 month following valve-in-valve implantation, 35 (7.6%) patients died, 8 (1.7%) had major stroke, and 313 (92.6%) of surviving patients had good functional status (New York Heart Association class I/II). The overall 1-year Kaplan-Meier survival rate was 83.2% (95% CI, 80.8%-84.7%; 62 death events; 228 survivors). Patients in the stenosis group had worse 1-year survival (76.6%; 95% CI, 68.9%-83.1%; 34 deaths; 86 survivors) in comparison with the regurgitation group (91.2%; 95% CI, 85.7%-96.7%; 10 deaths; 76 survivors) and the combined group (83.9%; 95% CI, 76.8%-91%; 18 deaths; 66 survivors) (P = .01). Similarly, patients with small valves had worse 1-year survival (74.8% [95% CI, 66.2%-83.4%]; 27 deaths; 57 survivors) vs with intermediate-sized valves (81.8%; 95% CI, 75.3%-88.3%; 26 deaths; 92 survivors) and with large valves (93.3%; 95% CI, 85.7%-96.7%; 7 deaths; 73 survivors) (P = .001). Factors associated with mortality within 1 year included having small surgical bioprosthesis (≤21 mm; hazard ratio, 2.04; 95% CI, 1.14-3.67; P = .02) and baseline stenosis (vs regurgitation; hazard ratio, 3.07; 95% CI, 1.33-7.08; P = .008). CONCLUSIONS AND RELEVANCE: In this registry of patients who underwent transcatheter valve-in-valve implantation for degenerated bioprosthetic aortic valves, overall 1-year survival was 83.2%. Survival was lower among patients with small bioprostheses and those with predominant surgical valve stenosis.

Microaxial Flow Pump or Standard Care in Infarct-Related Cardiogenic Shock
Jacob Eifer Møller, Thomas Engstrøm, Lisette Okkels Jensen, Hans Eiskjær +4 more
2024· New England Journal of Medicine911doi:10.1056/nejmoa2312572

BACKGROUND: The effects of temporary mechanical circulatory support with a microaxial flow pump on mortality among patients with ST-segment elevation myocardial infarction (STEMI) complicated by cardiogenic shock remains unclear. METHODS: In an international, multicenter, randomized trial, we assigned patients with STEMI and cardiogenic shock to receive a microaxial flow pump (Impella CP) plus standard care or standard care alone. The primary end point was death from any cause at 180 days. A composite safety end point was severe bleeding, limb ischemia, hemolysis, device failure, or worsening aortic regurgitation. RESULTS: A total of 360 patients underwent randomization, of whom 355 were included in the final analysis (179 in the microaxial-flow-pump group and 176 in the standard-care group). The median age of the patients was 67 years, and 79.2% were men. Death from any cause occurred in 82 of 179 patients (45.8%) in the microaxial-flow-pump group and in 103 of 176 patients (58.5%) in the standard-care group (hazard ratio, 0.74; 95% confidence interval [CI], 0.55 to 0.99; P = 0.04). A composite safety end-point event occurred in 43 patients (24.0%) in the microaxial-flow-pump group and in 11 (6.2%) in the standard-care group (relative risk, 4.74; 95% CI, 2.36 to 9.55). Renal-replacement therapy was administered to 75 patients (41.9%) in the microaxial-flow-pump group and to 47 patients (26.7%) in the standard-care group (relative risk, 1.98; 95% CI, 1.27 to 3.09). CONCLUSIONS: The routine use of a microaxial flow pump with standard care in the treatment of patients with STEMI-related cardiogenic shock led to a lower risk of death from any cause at 180 days than standard care alone. The incidence of a composite of adverse events was higher with the use of the microaxial flow pump. (Funded by the Danish Heart Foundation and Abiomed; DanGer Shock ClinicalTrials.gov number, NCT01633502.).

Valve Academic Research Consortium 3: updated endpoint definitions for aortic valve clinical research
Philippe Généreux, Nicolò Piazza, Maria Alu, Tamim Nazif +4 more
2020· European Heart Journal890doi:10.1093/eurheartj/ehaa799

AIMS: The Valve Academic Research Consortium (VARC), founded in 2010, was intended to (i) identify appropriate clinical endpoints and (ii) standardize definitions of these endpoints for transcatheter and surgical aortic valve clinical trials. Rapid evolution of the field, including the emergence of new complications, expanding clinical indications, and novel therapy strategies have mandated further refinement and expansion of these definitions to ensure clinical relevance. This document provides an update of the most appropriate clinical endpoint definitions to be used in the conduct of transcatheter and surgical aortic valve clinical research. METHODS AND RESULTS: Several years after the publication of the VARC-2 manuscript, an in-person meeting was held involving over 50 independent clinical experts representing several professional societies, academic research organizations, the US Food and Drug Administration (FDA), and industry representatives to (i) evaluate utilization of VARC endpoint definitions in clinical research, (ii) discuss the scope of this focused update, and (iii) review and revise specific clinical endpoint definitions. A writing committee of independent experts was convened and subsequently met to further address outstanding issues. There were ongoing discussions with FDA and many experts to develop a new classification schema for bioprosthetic valve dysfunction and failure. Overall, this multi-disciplinary process has resulted in important recommendations for data reporting, clinical research methods, and updated endpoint definitions. New definitions or modifications of existing definitions are being proposed for repeat hospitalizations, access site-related complications, bleeding events, conduction disturbances, cardiac structural complications, and bioprosthetic valve dysfunction and failure (including valve leaflet thickening and thrombosis). A more granular 5-class grading scheme for paravalvular regurgitation (PVR) is being proposed to help refine the assessment of PVR. Finally, more specific recommendations on quality-of-life assessments have been included, which have been targeted to specific clinical study designs. CONCLUSIONS: Acknowledging the dynamic and evolving nature of less-invasive aortic valve therapies, further refinements of clinical research processes are required. The adoption of these updated and newly proposed VARC-3 endpoints and definitions will ensure homogenous event reporting, accurate adjudication, and appropriate comparisons of clinical research studies involving devices and new therapeutic strategies.

Five-Year Outcomes with PCI Guided by Fractional Flow Reserve
Panagiotis Xaplanteris, Stéphane Fournier, Nico H.J. Pijls, William F. Fearon +4 more
2018· New England Journal of Medicine870doi:10.1056/nejmoa1803538

BACKGROUND: We hypothesized that fractional flow reserve (FFR)-guided percutaneous coronary intervention (PCI) would be superior to medical therapy as initial treatment in patients with stable coronary artery disease. METHODS: Among 1220 patients with angiographically significant stenoses, those in whom at least one stenosis was hemodynamically significant (FFR, ≤0.80) were randomly assigned to FFR-guided PCI plus medical therapy or to medical therapy alone. Patients in whom all stenoses had an FFR of more than 0.80 received medical therapy and were entered into a registry. The primary end point was a composite of death, myocardial infarction, or urgent revascularization. RESULTS: A total of 888 patients underwent randomization (447 patients in the PCI group and 441 in the medical-therapy group). At 5 years, the rate of the primary end point was lower in the PCI group than in the medical-therapy group (13.9% vs. 27.0%; hazard ratio, 0.46; 95% confidence interval [CI], 0.34 to 0.63; P<0.001). The difference was driven by urgent revascularizations, which occurred in 6.3% of the patients in the PCI group as compared with 21.1% of those in the medical-therapy group (hazard ratio, 0.27; 95% CI, 0.18 to 0.41). There were no significant differences between the PCI group and the medical-therapy group in the rates of death (5.1% and 5.2%, respectively; hazard ratio, 0.98; 95% CI, 0.55 to 1.75) or myocardial infarction (8.1% and 12.0%; hazard ratio, 0.66; 95% CI, 0.43 to 1.00). There was no significant difference in the rate of the primary end point between the PCI group and the registry cohort (13.9% and 15.7%, respectively; hazard ratio, 0.88; 95% CI, 0.55 to 1.39). Relief from angina was more pronounced after PCI than after medical therapy. CONCLUSIONS: In patients with stable coronary artery disease, an initial FFR-guided PCI strategy was associated with a significantly lower rate of the primary composite end point of death, myocardial infarction, or urgent revascularization at 5 years than medical therapy alone. Patients without hemodynamically significant stenoses had a favorable long-term outcome with medical therapy alone. (Funded by St. Jude Medical and others; FAME 2 ClinicalTrials.gov number, NCT01132495 .).

Extracorporeal Life Support in Infarct-Related Cardiogenic Shock
Hölger Thiele, Uwe Zeymer, İbrahim Akın, Michael Behnes +4 more
2023· New England Journal of Medicine788doi:10.1056/nejmoa2307227

BACKGROUND: Extracorporeal life support (ECLS) is increasingly used in the treatment of infarct-related cardiogenic shock despite a lack of evidence regarding its effect on mortality. METHODS: In this multicenter trial, patients with acute myocardial infarction complicated by cardiogenic shock for whom early revascularization was planned were randomly assigned to receive early ECLS plus usual medical treatment (ECLS group) or usual medical treatment alone (control group). The primary outcome was death from any cause at 30 days. Safety outcomes included bleeding, stroke, and peripheral vascular complications warranting interventional or surgical therapy. RESULTS: A total of 420 patients underwent randomization, and 417 patients were included in final analyses. At 30 days, death from any cause had occurred in 100 of 209 patients (47.8%) in the ECLS group and in 102 of 208 patients (49.0%) in the control group (relative risk, 0.98; 95% confidence interval [CI], 0.80 to 1.19; P = 0.81). The median duration of mechanical ventilation was 7 days (interquartile range, 4 to 12) in the ECLS group and 5 days (interquartile range, 3 to 9) in the control group (median difference, 1 day; 95% CI, 0 to 2). The safety outcome consisting of moderate or severe bleeding occurred in 23.4% of the patients in the ECLS group and in 9.6% of those in the control group (relative risk, 2.44; 95% CI, 1.50 to 3.95); peripheral vascular complications warranting intervention occurred in 11.0% and 3.8%, respectively (relative risk, 2.86; 95% CI, 1.31 to 6.25). CONCLUSIONS: In patients with acute myocardial infarction complicated by cardiogenic shock with planned early revascularization, the risk of death from any cause at the 30-day follow-up was not lower among the patients who received ECLS therapy than among those who received medical therapy alone. (Funded by the Else Kröner Fresenius Foundation and others; ECLS-SHOCK ClinicalTrials.gov number, NCT03637205.).

Tailored Atrial Substrate Modification Based on Low-Voltage Areas in Catheter Ablation of Atrial Fibrillation
Sascha Rolf, Simon Kircher, Arash Arya, Charlotte Eitel +4 more
2014· Circulation Arrhythmia and Electrophysiology571doi:10.1161/circep.113.001251

BACKGROUND: Reduced electrogram amplitude has been shown to correlate with diseased myocardium. We describe a novel individualized approach for catheter ablation of atrial fibrillation (AF) based on low-voltage areas (LVAs) in the left atrium (LA). We sought to assess (1) the incidence of LVAs in patients undergoing AF catheter ablation, (2) the distribution of LVAs within the LA, and (3) the effect of an individualized ablation strategy on long-term rhythm outcomes. METHODS AND RESULTS: In 178 patients with paroxysmal or persistent AF, LA voltage maps were created during sinus rhythm after circumferential pulmonary vein isolation. Subsequent substrate modification was confined to the presence of LVA (<0.5 mV) and inducible regular atrial tachycardias. LVAs were identified in 35% and 10% of patients with persistent and paroxysmal AF, respectively. The LA roof and the anterior, septal, and posterior wall LA were most often affected. The 12-month atrial tachycardias/AF-free survival was 62% for patients without LVAs and 70% for patients with LVAs and tailored substrate modification (P=0.3). Success rate in a comparison group of 26 LVA patients without further substrate modification was 27%. CONCLUSIONS: LVAs can be found at preferred sites in 10% of patients with paroxysmal AF and in 35% of patients with persistent AF. This is the first clinical report describing a consistent voltage-based approach for substrate modification in addition to circumferential pulmonary vein isolation irrespective of AF type. Application of this limited individualized approach may have the potential to compensate for the impaired 12-month outcome of patients with endocardial structural defects.

Off-Pump versus On-Pump Coronary-Artery Bypass Grafting in Elderly Patients
Anno Diegeler, Jochen Börgermann, Utz Kappert, Martin Breuer +4 more
2013· New England Journal of Medicine521doi:10.1056/nejmoa1211666

BACKGROUND: The benefits of coronary-artery bypass grafting (CABG) without cardiopulmonary bypass in the elderly are still undetermined. METHODS: We randomly assigned patients 75 years of age or older who were scheduled for elective first-time CABG to undergo the procedure either without cardiopulmonary bypass (off-pump CABG) or with it (on-pump CABG). The primary end point was a composite of death, stroke, myocardial infarction, repeat revascularization, or new renal-replacement therapy at 30 days and at 12 months after surgery. RESULTS: A total of 2539 patients underwent randomization. At 30 days after surgery, there was no significant difference between patients who underwent off-pump surgery and those who underwent on-pump surgery in terms of the composite outcome (7.8% vs. 8.2%; odds ratio, 0.95; 95% confidence interval [CI], 0.71 to 1.28; P=0.74) or four of the components (death, stroke, myocardial infarction, or new renal-replacement therapy). Repeat revascularization occurred more frequently after off-pump CABG than after on-pump CABG (1.3% vs. 0.4%; odds ratio, 2.42; 95% CI, 1.03 to 5.72; P=0.04). At 12 months, there was no significant between-group difference in the composite end point (13.1% vs. 14.0%; hazard ratio, 0.93; 95% CI, 0.76 to 1.16; P=0.48) or in any of the individual components. Similar results were obtained in a per-protocol analysis that excluded the 177 patients who crossed over from the assigned treatment to the other treatment. CONCLUSIONS: In patients 75 years of age or older, there was no significant difference between on-pump and off-pump CABG with regard to the composite outcome of death, stroke, myocardial infarction, repeat revascularization, or new renal-replacement therapy within 30 days and within 12 months after surgery. (Funded by Maquet; GOPCABE ClinicalTrials.gov number, NCT00719667.).

Impella Support for Acute Myocardial Infarction Complicated by Cardiogenic Shock
Benedikt Schrage, Karim Ibrahim, Tobias Loehn, Nikos Werner +4 more
2019· Circulation513doi:10.1161/circulationaha.118.036614

BACKGROUND: Percutaneous mechanical circulatory support devices are increasingly used in acute myocardial infarction complicated by cardiogenic shock (AMI-CS), despite limited evidence for their effectiveness. The aim of this study was to evaluate outcomes associated with use of the Impella device compared with intra-aortic balloon pump (IABP) and medical treatment in patients with AMI-CS. METHODS: Data of patients with AMI-CS treated with the Impella device at European tertiary care hospitals were collected retrospectively. All patients underwent early revascularization and received optimal medical treatment. Using IABP-SHOCK II (Intraaortic Balloon Pump in Cardiogenic Shock II) trial inclusion and exclusion criteria, 372 patients were identified and included in this analysis. These patients were matched to 600 patients from the IABP-SHOCK II trial. The following baseline criteria were used as matching parameters: age, sex, mechanical ventilation, ejection fraction, prior cardiopulmonary resuscitation, and lactate. Primary end point was 30-day all-cause mortality. RESULTS: In total, 237 patients treated with an Impella could be matched to 237 patients from the IABP-SHOCK II trial. Baseline parameters were similarly distributed after matching. There was no significant difference in 30-day all-cause mortality (48.5% versus 46.4%, P=0.64). Severe or life-threatening bleeding (8.5% versus 3.0%, P<0.01) and peripheral vascular complications (9.8% versus 3.8%, P=0.01) occurred significantly more often in the Impella group. Limiting the analysis to IABP-treated patients as a control group did not change the results. CONCLUSIONS: In this retrospective analysis of patients with AMI-CS, the use of an Impella device was not associated with lower 30-day mortality compared with matched patients from the IABP-SHOCK II trial treated with an IABP or medical therapy. To further evaluate this, a large randomized trial is warranted to determine the effect of the Impella device on outcome in patients with AMI-CS. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov . Unique identifier: NCT03313687.

The G Protein–Gated Potassium Current I K,ACh Is Constitutively Active in Patients With Chronic Atrial Fibrillation
Dobromir Dobrev, Adina Friedrich, Niels Voigt, Norbert Jost +4 more
2005· Circulation460doi:10.1161/circulationaha.105.575332

BACKGROUND: The molecular mechanism of increased background inward rectifier current (IK1) in atrial fibrillation (AF) is not fully understood. We tested whether constitutively active acetylcholine (ACh)-activated I(K,ACh) contributes to enhanced basal conductance in chronic AF (cAF). METHODS AND RESULTS: Whole-cell and single-channel currents were measured with standard voltage-clamp techniques in atrial myocytes from patients with sinus rhythm (SR) and cAF. The selective I(K,ACh) blocker tertiapin was used for inhibition of I(K,ACh). Whole-cell basal current was larger in cAF than in SR, whereas carbachol (CCh)-activated I(K,ACh) was lower in cAF than in SR. Tertiapin (0.1 to 100 nmol/L) reduced I(K,ACh) in a concentration-dependent manner with greater potency in cAF than in SR (-logIC50: 9.1 versus 8.2; P<0.05). Basal current contained a tertiapin-sensitive component that was larger in cAF than in SR (tertiapin [10 nmol/L]-sensitive current at -100 mV: cAF, -6.7+/-1.2 pA/pF, n=16/5 [myocytes/patients] versus SR, -1.7+/-0.5 pA/pF, n=24/8), suggesting contribution of constitutively active I(K,ACh) to basal current. In single-channel recordings, constitutively active I(K,ACh) was prominent in cAF but not in SR (channel open probability: cAF, 5.4+/-0.7%, n=19/9 versus SR, 0.1+/-0.05%, n=16/9; P<0.05). Moreover, IK1 channel open probability was higher in cAF than in SR (13.4+/-0.4%, n=19/9 versus 11.4+/-0.7%, n=16/9; P<0.05) without changes in other channel characteristics. CONCLUSIONS: Our results demonstrate that larger basal inward rectifier K+ current in cAF consists of increased IK1 activity and constitutively active I(K,ACh). Blockade of I(K,ACh) may represent a new therapeutic target in AF.

Monocytes coexpress endothelial and macrophagocytic lineage markers and form cord-like structures in Matrigel® under angiogenic conditions
Alexander Schmeißer
2001· Cardiovascular Research416doi:10.1016/s0008-6363(00)00270-4

OBJECTIVES: It has been shown that circulating human non-adherent CD34+ cells coexpressing vascular endothelial growth factor (VEGF)-R2 and AC133 have the capacity to differentiate into adherent mature endothelial cells. However, prior studies have demonstrated that a much bigger subset of primary adherent mononuclear cells can also form endothelial progenitor cells (EPC). To determine the origin of the latter cell population we tested the hypothesis: do monocytes as a firmly adherent and plastic cell type have the potential to differentiate into an endothelial phenotype. METHODS: CD34-/CD14+ monocytes were isolated from human peripheral blood by adherence separation and magnetic bead selection (purity >90%) and cultured on fibronectin-coated plastic dishes (medium containing VEGF 10 ng/ml, basic fibroblast growth factor (bFGF) 2 ng/ml, insulin like growth factor (IGF-1) 1 ng/ml, 20% fetal calf serum). RESULTS: After 2 weeks of culture, using fluorescence activated cell analysis we observed a new expression of the endothelial markers von Willebrand factor (vWf), VE-cadherin (VE) and ec-NOS in 45.2, 12.4 and 9.8% of the cells, respectively. The proportion of cells expressing these markers further increased after 4 weeks (94.2, 89.7 and 58.8% of these cells, respectively). The proportion of CD45 expressing cells remained unchanged during this period. However, after 14 days the specific macrophage antigen CD68 was newly expressed in 62% of the analysed cells with a further increase to 90% after 28 days of culture. In three-dimensional gel (Matrigel the formation of cord- and tubular-like structures was observed. CONCLUSION: The present data indicate that under angiogenic stimulation macrophages develop an endothelial phenotype with expression of specific surface markers and even form cord- and tubular-like structures in vitro suggesting that this cell population may be recruited for vasculogenesis.

Effect of High-Intensity Interval Training, Moderate Continuous Training, or Guideline-Based Physical Activity Advice on Peak Oxygen Consumption in Patients With Heart Failure With Preserved Ejection Fraction
Stephan Mueller, Ephraim B. Winzer, André Duvinage, Andreas B. Gevaert +4 more
2021· JAMA341doi:10.1001/jama.2020.26812

Importance: Endurance exercise is effective in improving peak oxygen consumption (peak V̇o2) in patients with heart failure with preserved ejection fraction (HFpEF). However, it remains unknown whether differing modes of exercise have different effects. Objective: To determine whether high-intensity interval training, moderate continuous training, and guideline-based advice on physical activity have different effects on change in peak V̇o2 in patients with HFpEF. Design, Setting, and Participants: Randomized clinical trial at 5 sites (Berlin, Leipzig, and Munich, Germany; Antwerp, Belgium; and Trondheim, Norway) from July 2014 to September 2018. From 532 screened patients, 180 sedentary patients with chronic, stable HFpEF were enrolled. Outcomes were analyzed by core laboratories blinded to treatment groups; however, the patients and staff conducting the evaluations were not blinded. Interventions: Patients were randomly assigned (1:1:1; n = 60 per group) to high-intensity interval training (3 × 38 minutes/week), moderate continuous training (5 × 40 minutes/week), or guideline control (1-time advice on physical activity according to guidelines) for 12 months (3 months in clinic followed by 9 months telemedically supervised home-based exercise). Main Outcomes and Measures: Primary end point was change in peak V̇o2 after 3 months, with the minimal clinically important difference set at 2.5 mL/kg/min. Secondary end points included changes in metrics of cardiorespiratory fitness, diastolic function, and natriuretic peptides after 3 and 12 months. Results: Among 180 patients who were randomized (mean age, 70 years; 120 women [67%]), 166 (92%) and 154 (86%) completed evaluation at 3 and 12 months, respectively. Change in peak V̇o2 over 3 months for high-intensity interval training vs guideline control was 1.1 vs -0.6 mL/kg/min (difference, 1.5 [95% CI, 0.4 to 2.7]); for moderate continuous training vs guideline control, 1.6 vs -0.6 mL/kg/min (difference, 2.0 [95% CI, 0.9 to 3.1]); and for high-intensity interval training vs moderate continuous training, 1.1 vs 1.6 mL/kg/min (difference, -0.4 [95% CI, -1.4 to 0.6]). No comparisons were statistically significant after 12 months. There were no significant changes in diastolic function or natriuretic peptides. Acute coronary syndrome was recorded in 4 high-intensity interval training patients (7%), 3 moderate continuous training patients (5%), and 5 guideline control patients (8%). Conclusions and Relevance: Among patients with HFpEF, there was no statistically significant difference in change in peak V̇o2 at 3 months between those assigned to high-intensity interval vs moderate continuous training, and neither group met the prespecified minimal clinically important difference compared with the guideline control. These findings do not support either high-intensity interval training or moderate continuous training compared with guideline-based physical activity for patients with HFpEF. Trial Registration: ClinicalTrials.gov Identifier: NCT02078947.

Molecular Basis of Downregulation of G-Protein–Coupled Inward Rectifying K+Current (IK,ACh) in Chronic Human Atrial Fibrillation
Dobromir Dobrev, Eva Graf, Erich Wettwer, Herbert M. Himmel +4 more
2001· Circulation322doi:10.1161/hc4601.099466

BACKGROUND: Clinical and experimental evidence suggest that the parasympathetic nervous system is involved in the pathogenesis of atrial fibrillation (AF). However, it is unclear whether changes in G-protein-coupled inward rectifying K(+) current (I(K,ACh)) contribute to chronic AF. METHODS AND RESULTS: In the present study, we used electrophysiological recordings and competitive reverse-transcription polymerase chain reaction to study changes in I(K,ACh) and the level of the I(K,ACh) GIRK4 subunit in isolated human atrial myocytes and the atrial tissue of 39 patients with sinus rhythm and 24 patients with chronic AF. The density of I(K,ACh) was approximately 50% smaller in myocytes from patients with AF compared with those in sinus rhythm, and this was accompanied by decreased levels of GIRK4 mRNA. The current density of the inward rectifying K(+) current (I(K1)) was 2-fold larger during AF than in sinus rhythm, in correspondence with an increase in Kir2.1 mRNA. The larger I(K1) in AF is consistent with more negative membrane potentials in right atrial trabeculae from AF patients. Moreover, action potential duration was reduced in AF, and the action potential shortening produced by muscarinic receptor stimulation was attenuated, indicating that the changes of I(K1) and I(K,ACh) were functionally relevant. CONCLUSIONS: Chronic human AF induces transcriptionally mediated upregulation of I(K1) but downregulation of I(K,ACh) and attenuates the muscarinic receptor-mediated shortening of atrial action potentials. This suggests that atrial myocytes adapt to a chronically high rate by downregulating I(K,ACh) to counteract the shortening of the atrial effective refractory period due to electrical remodeling.

Cerebral Embolic Protection during Transcatheter Aortic-Valve Replacement
Samir Kapadia, Raj Makkar, Martin B. Leon, Mohamed Abdel‐Wahab +4 more
2022· New England Journal of Medicine319doi:10.1056/nejmoa2204961

BACKGROUND: Transcatheter aortic-valve replacement (TAVR) for the treatment of aortic stenosis can lead to embolization of debris. Capture of debris by devices that provide cerebral embolic protection (CEP) may reduce the risk of stroke. METHODS: We randomly assigned patients with aortic stenosis in a 1:1 ratio to undergo transfemoral TAVR with CEP (CEP group) or without CEP (control group). The primary end point was stroke within 72 hours after TAVR or before discharge (whichever came first) in the intention-to-treat population. Disabling stroke, death, transient ischemic attack, delirium, major or minor vascular complications at the CEP access site, and acute kidney injury were also assessed. A neurology professional examined all the patients at baseline and after TAVR. RESULTS: A total of 3000 patients across North America, Europe, and Australia underwent randomization; 1501 were assigned to the CEP group and 1499 to the control group. A CEP device was successfully deployed in 1406 of the 1489 patients (94.4%) in whom an attempt was made. The incidence of stroke within 72 hours after TAVR or before discharge did not differ significantly between the CEP group and the control group (2.3% vs. 2.9%; difference, -0.6 percentage points; 95% confidence interval, -1.7 to 0.5; P = 0.30). Disabling stroke occurred in 0.5% of the patients in the CEP group and in 1.3% of those in the control group. There were no substantial differences between the CEP group and the control group in the percentage of patients who died (0.5% vs. 0.3%); had a stroke, a transient ischemic attack, or delirium (3.1% vs. 3.7%); or had acute kidney injury (0.5% vs. 0.5%). One patient (0.1%) had a vascular complication at the CEP access site. CONCLUSIONS: Among patients with aortic stenosis undergoing transfemoral TAVR, the use of CEP did not have a significant effect on the incidence of periprocedural stroke, but on the basis of the 95% confidence interval around this outcome, the results may not rule out a benefit of CEP during TAVR. (Funded by Boston Scientific; PROTECTED TAVR ClinicalTrials.gov number, NCT04149535.).

Practical ways to reduce radiation dose for patients and staff during device implantations and electrophysiological procedures
Hein Heidbüchel, Fred H.M. Wittkampf, E. Vañó, Sabine Ernst +4 more
2014· EP Europace310doi:10.1093/europace/eut409

Despite the advent of non-fluoroscopic technology, fluoroscopy remains the cornerstone of imaging in most interventional electrophysiological procedures, from diagnostic studies over ablation interventions to device implantation. Moreover, many patients receive additional X-ray imaging, such as cardiac computed tomography and others. More and more complex procedures have the risk to increase the radiation exposure, both for the patients and the operators. The professional lifetime attributable excess cancer risk may be around 1 in 100 for the operators, the same as for a patient undergoing repetitive complex procedures. Moreover, recent reports have also hinted at an excess risk of brain tumours among interventional cardiologists. Apart from evaluating the need for and justifying the use of radiation to assist their procedures, physicians have to continuously explore ways to reduce the radiation exposure. After an introduction on how to quantify the radiation exposure and defining its current magnitude in electrophysiology compared with the other sources of radiation, this position paper wants to offer some very practical advice on how to reduce exposure to patients and staff. The text describes how customization of the X-ray system, workflow adaptations, and shielding measures can be implemented in the cath lab. The potential and the pitfalls of different non-fluoroscopic guiding technologies are discussed. Finally, we suggest further improvements that can be implemented by both the physicians and the industry in the future. We are confident that these suggestions are able to reduce patient and operator exposure by more than an order of magnitude, and therefore think that these recommendations are worth reading and implementing by any electrophysiological operator in the field.

A prospective randomized evaluation of the TriGuard™ HDH embolic DEFLECTion device during transcatheter aortic valve implantation: results from the DEFLECT III trial
Alexandra J. Lansky, Joachim Schöfer, Didier Tchétché, Pieter R. Stella +4 more
2015· European Heart Journal309doi:10.1093/eurheartj/ehv191

AIMS: To evaluate the safety, efficacy, and performance of the TriGuard™ HDH Embolic Deflection Device (TriGuard) compared with no cerebral protection in patients undergoing transcatheter aortic valve implantation (TAVI). METHODS AND RESULTS: From February 2014 to March 2015, 85 subjects undergoing TAVI at 13 centres in Europe and Israel were randomized to TriGuard protection vs. no protection. Subjects underwent neurologic and cognitive evaluation at baseline, pre-discharge and 30 days; cerebral diffusion-weighted magnetic resonance imaging was performed at 4 ± 2 days post-procedure and at 30 days. Technical success, which included complete 3-vessel cerebral coverage, was achieved in 88.9% (40/45) of cases. The primary in-hospital procedural safety endpoint (death, stroke, life-threatening or disabling bleeding, stage 2 or 3 acute kidney injury, or major vascular complications) occurred in 21.7% of TriGuard and 30.8% of control subjects (P = 0.34). In the Per Treatment population (subjects with complete three-vessel cerebral coverage), TriGuard use was associated with greater freedom from new ischaemic brain lesions (26.9 vs. 11.5%), fewer new neurologic deficits detected by the National Institutes of Health Stroke Scale (3.1 vs. 15.4%), improved Montreal Cognitive Assessment (MoCA) scores, better performance on a delayed memory task (P = 0.028) at discharge, and a >2-fold increase in recovery of normal cognitive function (MoCA score >26) at 30 days. CONCLUSION: TriGuard cerebral protection during TAVI is safe and complete cerebral vessel coverage was achieved in 89% of subjects. In this exploratory study, subjects undergoing protected TAVI had more freedom from ischaemic brain lesions, fewer neurologic deficits, and improved cognitive function in some domains at discharge and 30 days compared with controls.

L-Type Ca 2+ Current Downregulation in Chronic Human Atrial Fibrillation Is Associated With Increased Activity of Protein Phosphatases
Torsten Christ, Peter Boknı́k, Stefan Wöhrl, Erich Wettwer +4 more
2004· Circulation295doi:10.1161/01.cir.0000145659.80212.6a

BACKGROUND: Although downregulation of L-type Ca2+ current (I(Ca,L)) in chronic atrial fibrillation (AF) is an important determinant of electrical remodeling, the molecular mechanisms are not fully understood. Here, we tested whether reduced I(Ca,L) in AF is associated with alterations in phosphorylation-dependent channel regulation. METHODS AND RESULTS: We used whole-cell voltage-clamp technique and biochemical assays to study regulation and expression of I(Ca,L) in myocytes and atrial tissue from 148 patients with sinus rhythm (SR) and chronic AF. Basal I(Ca,L) at +10 mV was smaller in AF than in SR (-3.8+/-0.3 pA/pF, n=138/37 [myocytes/patients] and -7.6+/-0.4 pA/pF, n=276/86, respectively; P<0.001), though protein levels of the pore-forming alpha1c and regulatory beta2a channel subunits were not different. In both groups, norepinephrine (0.01 to 10 micromol/L) increased I(Ca,L) with a similar maximum effect and comparable potency. Selective blockers of kinases revealed that basal I(Ca,L) was enhanced by Ca2+/calmodulin-dependent protein kinase II in SR but not in AF. Norepinephrine-activated I(Ca,L) was larger with protein kinase C block in SR only, suggesting decreased channel phosphorylation in AF. The type 1 and type 2A phosphatase inhibitor okadaic acid increased basal I(Ca,L) more effectively in AF than in SR, which was compatible with increased type 2A phosphatase but not type 1 phosphatase protein expression and higher phosphatase activity in AF. CONCLUSIONS: In AF, increased protein phosphatase activity contributes to impaired basal I(Ca,L). We propose that protein phosphatases may be potential therapeutic targets for AF treatment.

Role of I Kur in Controlling Action Potential Shape and Contractility in the Human Atrium
Erich Wettwer, Ottó Hála, Torsten Christ, Jürgen F. Heubach +4 more
2004· Circulation292doi:10.1161/01.cir.0000145155.60288.71

BACKGROUND: The ultrarapid outward current I(Kur) is a major repolarizing current in human atrium and a potential target for treating atrial arrhythmias. The effects of selective block of I(Kur) by low concentrations of 4-aminopyridine or the biphenyl derivative AVE 0118 were investigated on right atrial action potentials (APs) in trabeculae from patients in sinus rhythm (SR) or chronic atrial fibrillation (AF). METHODS AND RESULTS: AP duration at 90% repolarization (APD90) was shorter in AF than in SR (300+/-16 ms, n=6, versus 414+/-10 ms, n=15), whereas APD20 was longer (35+/-9 ms in AF versus 5+/-2 ms in SR, P<0.05). 4-Aminopyridine (5 micromol/L) elevated the plateau to more positive potentials from -21+/-3 to -6+/-3 mV in SR and 0+/-3 to +12+/-3 mV in AF. 4-Aminopyridine reversibly shortened APD90 from 414+/-10 to 350+/-10 ms in SR but prolonged APD90 from 300+/-16 to 320+/-13 ms in AF. Similar results were obtained with AVE 0118 (6 micromol/L). Computer simulations of I(Kur) block in human atrial APs predicted secondary increases in I(Ca,L) and in the outward rectifiers I(Kr) and I(Ks), with smaller changes in AF than SR. The indirect increase in I(Ca,L) was supported by a positive inotropic effect of 4-aminopyridine without direct effects on I(Ca,L) in atrial but not ventricular preparations. In accordance with the model predictions, block of I(Kr) with E-4031 converted APD shortening effects of I(Kur) block in SR into AP prolongation. CONCLUSIONS: Whether inhibition of I(Kur) prolongs or shortens APD depends on the disease status of the atria and is determined by the level of electrical remodeling.

Low-Voltage Myocardium-Guided Ablation Trial of Persistent Atrial Fibrillation
Yan Huo, Thomas Gaspar, Robert Schönbauer, Maciej Wójcik +4 more
2022· NEJM Evidence277doi:10.1056/evidoa2200141

BACKGROUND: Clinically effective ablation approaches for patients with persistent atrial fibrillation (AF) are still being debated. So far, ablation targets and strategies beyond pulmonary vein isolation (PVI) have failed to show systematic outcome improvement in randomized controlled clinical trials. METHODS: We conducted a multicenter, randomized trial to determine whether PVI plus individualized substrate ablation of atrial low-voltage myocardium improves outcome in patients with persistent AF. We randomly assigned 324 patients in a 1:1 ratio to receive PVI alone (163 patients; PVI only) or PVI plus substrate modification (161 patients; PVI+SM). The primary study end point was the first recurrence of an atrial arrhythmia longer than 30 seconds after single ablation, with 3 months blanking, using serial 7-day electrocardiogram recordings over 12 months of observation. Patients were also encouraged to receive implantable cardiac monitors. RESULTS: The primary study end point occurred in 75 PVI-only patients (50%) and in 54 PVI+SM patients (35%) (Kaplan–Meier event rate estimates: hazard ratio=0.62, 95% confidence interval [CI]=0.43 to 0.88, log rank P=0.006). Adverse events occurred in three PVI-only patients (1.8%) and in six PVI+SM patients (3.7%) (difference: −1.9 percentage points, 95% CI=−5.5 to 1.7 percentage points). Implant monitoring was used in 242 patients. Among them, 65 PVI-only patients (55%) versus 47 PVI+SM patients (39%) experienced recurrences (difference: 15 percentage points, 95% CI=3 to 28 percentage points). CONCLUSIONS: In this randomized trial, PVI plus individualized ablation of atrial low-voltage myocardium significantly improved outcomes in patients with persistent AF. (ClinicalTrials.gov number, NCT02732626.)

Molecular Determinants of Altered Ca 2+ Handling in Human Chronic Atrial Fibrillation
Ali El‐Armouche, Peter Boknı́k, Thomas Eschenhagen, Lucie Carrier +3 more
2006· Circulation277doi:10.1161/circulationaha.106.636845

BACKGROUND: Abnormal Ca2+ handling may contribute to impaired atrial contractility and arrhythmogenesis in human chronic atrial fibrillation (cAF). Here, we assessed the phosphorylation levels of key proteins involved in altered Ca2+ handling and contractility in cAF patients. METHODS AND RESULTS: Total and phosphorylation levels of Ca2+-handling and myofilament proteins were analyzed by Western blotting in right atrial appendages of 49 patients in sinus rhythm and 52 cAF patients. We found a higher total activity of type 1 (PP1) and type 2A phosphatases in cAF, which was associated with inhomogeneous changes of protein phosphorylation in the cellular compartments, ie, lower protein kinase A (PKA) phosphorylation of myosin binding protein-C (Ser-282 site) at the thick myofilaments but preserved PKA phosphorylation of troponin I at the thin myofilaments and enhanced PKA (Ser-16 site) and Ca2+-calmodulin protein kinase (Thr-17 site) phosphorylation of phospholamban. PP1 activity at sarcoplasmic reticulum is controlled by inhibitor-1 (I-1), which blocks PP1 in its PKA-phosphorylated form only. In cAF, the ratio of Thr-35-phosphorylated to total I-1 was 10-fold higher, which suggests that the enhanced phosphorylation of phospholamban may result from a stronger PP1 inhibition by PKA-hyperphosphorylated (activated) I-1. CONCLUSIONS: Altered Ca2+ handling in cAF is associated with impaired phosphorylation of myosin binding protein-C, which may contribute to the contractile dysfunction after cardioversion. The hyperphosphorylation of phospholamban probably results from enhanced inhibition of sarcoplasmic PP1 by hyperphosphorylated I-1 and may reinforce the leakiness of ryanodine channels in cAF. Restoration of sarcoplasmic reticulum-associated PP1 function may represent a new therapeutic option for treatment of atrial fibrillation.